DSP Sine Wave Inverter/UPS
PARAMETERS |
MODEL |
model |
R925/12V |
R1125/12V |
R1825/24V |
R2225/24V |
R2625/24V |
R3725/48V |
No Load Current |
< 2.04 |
< 2.5A |
< 2.5A |
Output Voltage @ No Load |
< 240VAC @12.O VDC |
< 240VAC @24.OVDC |
< 240VAC @48.OVDC |
Battery Current @ Full Load |
44A ±2A |
54A ±2A |
64A ±2A |
54A ±2A |
64A ±2A |
75A ±2A |
60A ±2A |
Over Load Alarm |
46A ±2A |
56A ±2A |
66A ±2A |
56A ±2A |
66 ±2A |
77A ±2A |
62A ±2A |
Battery Low Alarm |
10.6 ±0.2V |
21.2 ±0.2V |
21.2 ±0.2V |
21.2 ±0.2V |
42.4 ±0.2V |
Battery Low Shutdown |
10.4 ±0.2V |
20.8 ±0.2V |
20.8 ±0.2V |
20.8 ±0.2V |
41.6 ±0.2V |
Short Circuits Protection |
Yes |
Inverter Output Frequency |
50 ± 0.1Hz |
UPS MODE |
Main Input Volatge Range |
170V To 265V |
Mains AC Low Cut |
170VAC ± 10VAC |
Mains AC Low Cut Recovery |
180VAC ± 10VAC |
Mains AC High Cut |
265VAC ± 10VAC |
Mains AC High Cut Recovery |
255VAC ± 10VAC |
Maximum Change Over Time |
<8msec |
W-UPS MODE |
Mains Input Voltage Range |
90VAC To 290V |
Mains AC Low Cut |
90VAC ± 10VAC |
Mains AC Low Cut Recovery |
110VAC ± 10VAC |
Mains AC High Cut |
290VAC ± 10VAC |
Mains AC High Cut Recovery |
280VAC ± 10VAC |
Maximum Change Over Time |
<20msec |
CHARGING MODE |
Charging Current@220VAC |
15.0 ±2A |
Boost Voltage (Tub Mode) |
14.4V ±0.2v |
28.8V ±0.4V |
57.6V ±0.8V |
Boost Voltage (LA Mode) |
14.0V ±0.2v |
28.8V ±0.4V |
56V ±0.8V |
Boost Voltage (ENABLE Tub Mode) |
15.0V ±2V |
30.0V ±0.4V |
60.0V ±0.8V |
Boost Voltage (ENABLE LA Mode) |
15.0V ±2V |
30.0V ±0.4V |
60.0V ±0.8V |
Float Voltage |
13.6V ±2V |
27.2V ±0.4V |
54.4V ±0.8V |
Short Circuit |
Yes |
PROTECTION |
Battery Low Cut Off |
1 TIme |
Overload (Auto Retries) |
4 TIme |
Short Circuits (Auto Retries) |
3 TIme |
Over Temperature |
3 TIme |
Battery Over Charge |
Yes |
Input Protection |
Yes (Mains Fuse Blown/MCB Trip in Case of Short Circuit in Mains Mode) |